A hipot tester (hi pot tester or hy-pot tester) and instruments for Dielectric Withstand tests are used for performing either a series of or a specific electrical safety test on electrical components and products to ensure they meet operator safety requirements as well as comply with UL, CSA, IEC, and other standard certifying bodies. A high grade hipot medical safety analyzer must be able to perform high precision hi-pot testing and have reporting capabilities to indicate tested equipment falls within required specification.

Hipot Testers and Electrical Safety Analyzer - performs hipot testing, insulation resistance tests and ground bond tests. CaptivATE Automation Software is available.

Specialty Hipot Testers - used to perform high-voltage AC Hipot, ACDC Hipot and DC Hipot testing as well as insulation resistance testing and ground bond tests

Multi-Purpose Hipot Testers - performs insulation resistance testing, ground continuity and they have a broader testing range for AC Hipot, ACDC Hipot and DC Hipot tests. CaptivATE Automation software is availble.

Basic Hipot Testers - economical, easy-to-use Hipot testers that perform simple AC Hipot, ACDC Hipot and DC Hipot tests

**Note - All units come fully calibrated at time of purchase.**

The medical safety analyzer and hipot testers shown in the tables below represent some of the highest quality electrical safety test units available.

Hipot Testers and Electrical Safety Analyzers

G6000P Left - SMALL

Hybrid 2000 Left - SMALL
Guardian 6100 Plus
Hipot Tester and Medical Safety Analyzer*
Guardian 6000 Plus
Hipot Tester*
Hybrid 2000
Hipot Tester*
Other Capabilities Insulation Resistance and Simultaneous Ground Continuity (Ground Bond) and Hi-pot Testing
KEY FEATURES
AC Hipot

0.05-5.0kVAC
0.001 -40mAAC
HI/LO limits
Arc Detect; Filter
20A LC Scanner:
Earth, Enclosure, Patient, Pat. Aux
Functional Run:
(V), (A) or (VA)

0.05-5.0kVAC
0.001 -40mAAC
HI/LO limits
Arc Detect;
Filter

0.05 – 5kV
0.001 – 30mA
IReal , ITotal
HI/LO limits
Arc detect
DC Hipot 0.05 -6.0kVDC
0.0001-12mADC
HI/LO limits
Arc Detect;
Filter

0.05 -6.0kVDC
0.0001-12mADC
HI/LO limits
Arc Detect;
Filter

0.05 – 6kV
0.0001 – 10mA
HI/LO limits
Arc detect
Insulation Resistance (IR) 0.05-1kVDC
100k-50G
Ω
HI/LO limits
0.05-1kVDC
100k-50G
Ω
HI/LO limits
0.05 – 5kV
1M
Ω – 50GΩ
Ground Continuity (Ground Bond)

GB: 1-30A; 40A opt
0.1m
Ω- 510mΩ
6.0-15V AC
Twin PortTM: GB & Hipot
Other: OSC, PA

GB:1-30A; 40A opt
0.1m
Ω- 510mΩ
6.0-15V AC
Twin PortTM: GB & Hipot
Other: OSC, PA

DCR:
50m
Ω – 100mΩ
Other: OSC, PA

* CaptivATE Automation Software available

Top

MULTI-PURPOSE HIPOT TESTERS

1010 Left - SMALL

1050 Left - SMALL
Guardian 1010
Hipot Tester*

Guardian 1030
Hipot Tester*
Guardian 1030S
Hipot Tester*
Guardian 1050
Ground Bond Tester
Other Capabilities Insulation Resistance and Ground Continuity (Ground Bond) Testing
KEY FEATURES
AC Hipot

0.05-5.0kVAC0.001-30mAAC
IReal; ITotal
HI/LO limits
Arc detect

0.05-5.0kVAC
0.001-30mAAC
IReal; ITotal
HI/LO limits
Arc detect

0.05-5.0kVAC
0.001-30mAAC
IReal; ITotal
HI/LO limits
Arc detect

DC Hipot

0.05-6.0kVDC
.0001-10mA DC
HI/LO limits
Arc detect

0.05-6.0kVDC
.0001-10mA DC
HI/LO limits
Arc detect

Insulation Resistance (IR) 0.05-1kVDC
0.1M-50G
Ω
HI/LO limits

0.05-1kVDC
0.1M-50G
Ω
HI/LO limits

Ground Continuity (Ground Bond)

GC: 100mA DC
1
Ω Max
Other: OSC, PA

GC: 100mA DC
1
Ω Max
Other: OSC, PA

GC: 100mA DC
1
Ω Max
Other: OSC, PA

GB: 3-45A AC
0.1m
Ω- 510mΩ
1.0-8.0V AC

* CaptivATE Automation Software available

Top

SPECIALTY HIPOT TESTERS

G10KV AC Left - SMALL

Guardian 500VA Hipot Tester
Guardian 10KVAC Hipot Tester Guardian 12KVDC Hipot Tester Guardian 20KVDC Hipot Tester
Other Capabilities Insulation Resistance and Ground Continuity (Ground Bond) Testing.
KEY FEATURES
AC Hipot

0.05-5.0kVAC
0.001-100mAAC
0.0001-20mADC
HI/LO limits
Arc detect

0.1 -10.0kVAC
0.001-20mAAC
HI/LO limits
Arc detect

DC Hipot 0.05-6.0kVDC
0.0001-20mADC
HI/LO limits
Arc detect

0.1-12.0kVDC
0.0001-10mADC
HI/LO limits
Arc detect

0.1-20.0kVDC
0.0001-5mADC
HI/LO limits
Arc detect
Insulation Resistance (IR) 0.05-1kVDC
100k-50G
Ω
HI/LO limits

0.1-1kVDC
100k-50G
Ω
HI/LO limits

0.1-1kVDC
100k-50G
Ω
HI/LO limits
Ground Continuity
(Ground Bond)

Other: PA

Other: PA

Other: PA

Other: PA

Top

BASIC HIPOT TESTERS

Sentry 30 Plus Left - SMALL

Sentry 50 Plus Left - SMALL

Sentry 10 Plus
Hipot Tester
Sentry 20 Plus
Hipot Tester
Sentry 30 Plus
Hipot Tester
Sentry 50 Plus
Ground Bond Tester
Other Capabilities Insulation Resistance and Ground Continuity (Groundbond) Testing
KEY FEATURES
AC Hipot

0.05-5.0kVAC
1 mA-20mAAC
HI/LO limits
Arc detect

0.05-5.0kVAC
1mA-20mAAC
HI/LO limits
Arc detect

0.05-5.0kVAC
1mA-20mAAC
HI/LO limits
Arc detect

DC Hipot

0.05-6.0kVDC
0.1mA-5.0mADC
HI/LO limits
Arc detect

0.05-6.0kVDC
0.1mA-5.0mADC
HI/LO limits
Arc detect

Insulation Resistance (IR)

0.5-1kVDC
0.1M-50G
Ω

Ground Continuity
(Ground Bond)

GC: Programmable
0.1
Ω - 5Ω ± 2Ω
Other: OSC, PA

GC: Programmable
0.1
Ω - 5Ω ± 2Ω
Other: OSC, PA

GC: Programmable
0.1
Ω - 5Ω ± 2Ω
Other: OSC, PA

GB: 3-30A AC
0.1m
Ω- 510mΩ
1.0-8.0V AC

Top

Request documentation

 

Latest News

twitteryoutube

jun-2017
EM Test New ESD Simulator

NX 30 - New 30kV ESD Simulator with Bleed-off function.
more...


EM Test Surge Generator for Solar Panel testing
New vSurge NX 20
more...


3-phase Power Sources from EM Test
Netwave Series
more...


MPE - World First Gb Ethernet Filter
Low-Pass EMI Filter
more...


Rental solutions for EMC instrumentation
Accelonix Rental Service
more...


05-may-2017
Accelonix at E&A 2017
Accelonix exhibiting at Electronics & Applications 2017.
May 30 May to June 1th, Jaarbeurs Utrecht.


22-feb-2017
TestWay Seminar

DFx Software Tools to Optimize PCBA Manufacturing & Test Strategy.
April 4, Eindhoven


08-feb-2017
Yxlon FeinFocus

Non-Destructive X-ray Inspection Technology for Electronics.
more...


01-feb-2017
Aster twSystem

New system level PCB viewer.
more...


26-jan-2017
Hesse New BJ 955/959

New Bonder platform for Manual and Automated Heavy Wire Bonding.
more...


18-jan-2017
Akrometrix

Thermal Warpage & Strain Metrology Measurement Systems.
more...


27-nov-2016
CyberTECHNOLOGIES
Non-Contact 3D Surface Metrology Measurement Systems.
more...


15-nov-2016
TPT Wire Bonding Workshop
Learn about Wire Bonding and discover the TPT Solutions during this Free Workshop!

 


sep-2016
XRH Count
Revolution in automatic, contactless SMT component counting!
more...


june-2016
FEE EMC Seminar
Thank you for visiting us in St-Katelijne-Waver


may-2016
Teseq ITS 6006B
Radiated immunity test system up to 6GHz, Second Generation released
more...



Teseq NSG 4070B
RF immunity test system up to 1GHz. Now also supports draft version (2015) of ISO 7637-4
more...



Teseq NSG 4060
Meets new immunity testing requirements range 15kHz-150kHz
more...



MPE Plug-in Tempest Filters
Protect your IT systems with this range of convenient, plug-in TEMPEST filters
more...


mar-2016
Accelonix BV has moved!
Accelonix has moved to a new office space since March 12th 2016
more...


jan-2016
Data I/O LumenX
Data I/O Ultra-Fast eMMC Programming!
more...


Accelonix News Archive