Quadtech

HiPot Tester and Electrical Safety Testers

A hipot tester (hi pot tester or hy-pot tester) and instruments for Dielectric Withstand tests are used for performing either a series of or a specific electrical safety test on electrical components and products to ensure they meet operator safety requirements as well as comply with UL, CSA, IEC, and other standard certifying bodies. A high grade hipot medical safety analyzer must be able to perform high precision hi-pot testing and have reporting capabilities to indicate tested equipment falls within required specification.

Hipot Testers and Electrical Safety Analyzer - performs hipot testing, insulation resistance tests and ground bond tests. CaptivATE Automation Software is available.

Specialty Hipot Testers - used to perform high-voltage AC Hipot, ACDC Hipot and DC Hipot testing as well as insulation resistance testing and ground bond tests

Multi-Purpose Hipot Testers - performs insulation resistance testing, ground continuity and they have a broader testing range for AC Hipot, ACDC Hipot and DC Hipot tests. CaptivATE Automation software is availble.

Basic Hipot Testers - economical, easy-to-use Hipot testers that perform simple AC Hipot, ACDC Hipot and DC Hipot tests

**Note - All units come fully calibrated at time of purchase.**

The medical safety analyzer and hipot testers shown in the tables below represent some of the highest quality electrical safety test units available.

Hipot Testers and Electrical Safety Analyzers

G6000P Left - SMALL

Hybrid 2000 Left - SMALL
Guardian 6100 Plus
Hipot Tester and Medical Safety Analyzer*
Guardian 6000 Plus
Hipot Tester*
Hybrid 2000
Hipot Tester*
Other Capabilities Insulation Resistance and Simultaneous Ground Continuity (Ground Bond) and Hi-pot Testing
KEY FEATURES
AC Hipot

0.05-5.0kVAC
0.001 -40mAAC
HI/LO limits
Arc Detect; Filter
20A LC Scanner:
Earth, Enclosure, Patient, Pat. Aux
Functional Run:
(V), (A) or (VA)

0.05-5.0kVAC
0.001 -40mAAC
HI/LO limits
Arc Detect;
Filter

0.05 – 5kV
0.001 – 30mA
IReal , ITotal
HI/LO limits
Arc detect
DC Hipot 0.05 -6.0kVDC
0.0001-12mADC
HI/LO limits
Arc Detect;
Filter

0.05 -6.0kVDC
0.0001-12mADC
HI/LO limits
Arc Detect;
Filter

0.05 – 6kV
0.0001 – 10mA
HI/LO limits
Arc detect
Insulation Resistance (IR) 0.05-1kVDC
100k-50G
Ω
HI/LO limits
0.05-1kVDC
100k-50G
Ω
HI/LO limits
0.05 – 5kV
1M
Ω – 50GΩ
Ground Continuity (Ground Bond)

GB: 1-30A; 40A opt
0.1m
Ω- 510mΩ
6.0-15V AC
Twin PortTM: GB & Hipot
Other: OSC, PA

GB:1-30A; 40A opt
0.1m
Ω- 510mΩ
6.0-15V AC
Twin PortTM: GB & Hipot
Other: OSC, PA

DCR:
50m
Ω – 100mΩ
Other: OSC, PA

* CaptivATE Automation Software available

Top

MULTI-PURPOSE HIPOT TESTERS

1010 Left - SMALL

1050 Left - SMALL
Guardian 1010
Hipot Tester*

Guardian 1030
Hipot Tester*
Guardian 1030S
Hipot Tester*
Guardian 1050
Ground Bond Tester
Other Capabilities Insulation Resistance and Ground Continuity (Ground Bond) Testing
KEY FEATURES
AC Hipot

0.05-5.0kVAC0.001-30mAAC
IReal; ITotal
HI/LO limits
Arc detect

0.05-5.0kVAC
0.001-30mAAC
IReal; ITotal
HI/LO limits
Arc detect

0.05-5.0kVAC
0.001-30mAAC
IReal; ITotal
HI/LO limits
Arc detect

DC Hipot

0.05-6.0kVDC
.0001-10mA DC
HI/LO limits
Arc detect

0.05-6.0kVDC
.0001-10mA DC
HI/LO limits
Arc detect

Insulation Resistance (IR) 0.05-1kVDC
0.1M-50G
Ω
HI/LO limits

0.05-1kVDC
0.1M-50G
Ω
HI/LO limits

Ground Continuity (Ground Bond)

GC: 100mA DC
1
Ω Max
Other: OSC, PA

GC: 100mA DC
1
Ω Max
Other: OSC, PA

GC: 100mA DC
1
Ω Max
Other: OSC, PA

GB: 3-45A AC
0.1m
Ω- 510mΩ
1.0-8.0V AC

* CaptivATE Automation Software available

Top

SPECIALTY HIPOT TESTERS

G10KV AC Left - SMALL

Guardian 500VA Hipot Tester
Guardian 10KVAC Hipot Tester Guardian 12KVDC Hipot Tester Guardian 20KVDC Hipot Tester
Other Capabilities Insulation Resistance and Ground Continuity (Ground Bond) Testing.
KEY FEATURES
AC Hipot

0.05-5.0kVAC
0.001-100mAAC
0.0001-20mADC
HI/LO limits
Arc detect

0.1 -10.0kVAC
0.001-20mAAC
HI/LO limits
Arc detect

 

DC Hipot 0.05-6.0kVDC
0.0001-20mADC
HI/LO limits
Arc detect

 

0.1-12.0kVDC
0.0001-10mADC
HI/LO limits
Arc detect

0.1-20.0kVDC
0.0001-5mADC
HI/LO limits
Arc detect
Insulation Resistance (IR) 0.05-1kVDC
100k-50G
Ω
HI/LO limits

0.1-1kVDC
100k-50G
Ω
HI/LO limits

0.1-1kVDC
100k-50G
Ω
HI/LO limits
Ground Continuity
(Ground Bond)

Other: PA

Other: PA

Other: PA

Other: PA

Top

BASIC HIPOT TESTERS

Sentry 30 Plus Left - SMALL

Sentry 50 Plus Left - SMALL

Sentry 10 Plus
Hipot Tester
Sentry 20 Plus
Hipot Tester
Sentry 30 Plus
Hipot Tester
Sentry 50 Plus
Ground Bond Tester
Other Capabilities Insulation Resistance and Ground Continuity (Groundbond) Testing
KEY FEATURES
AC Hipot

0.05-5.0kVAC
1 mA-20mAAC
HI/LO limits
Arc detect

0.05-5.0kVAC
1mA-20mAAC
HI/LO limits
Arc detect

0.05-5.0kVAC
1mA-20mAAC
HI/LO limits
Arc detect

DC Hipot

0.05-6.0kVDC
0.1mA-5.0mADC
HI/LO limits
Arc detect

0.05-6.0kVDC
0.1mA-5.0mADC
HI/LO limits
Arc detect

Insulation Resistance (IR)

0.5-1kVDC
0.1M-50G
Ω

Ground Continuity
(Ground Bond)

GC: Programmable
0.1
Ω - 5Ω ± 2Ω
Other: OSC, PA

GC: Programmable
0.1
Ω - 5Ω ± 2Ω
Other: OSC, PA

GC: Programmable
0.1
Ω - 5Ω ± 2Ω
Other: OSC, PA

GB: 3-30A AC
0.1m
Ω- 510mΩ
1.0-8.0V AC

Top

Request documentation

 
Latest News

10-jun-2010
Finero
Launches their new QUANTI series®
more >>


06-apr-2010
Goepel electronic
In-System Emulation technology VarioTAP® expands to support Xilinx® FPGA
more >>


01-March-2010
New Accelonix website online


16-dec-2009
Goepel electronic
SCANFLEX JTAG/Boundary Scan extended test coverage for RS422/RS485-Interfaces
more >>


20-nov-2009
Data I/O
FlashCORE III Wins a 2009 Global Technology Award
more >>


13-nov-2009
Teseq
Introduces new & improved automotive emissions system
more >>


10-nov-2009
Goepel electronic
AXI System OptiCon X-Line 3D upgraded by double-sided AOI Inspection
more >>


12-okt-2009
Laplace Instruments ltd
Introduces new 61000-4-6 Conducted Immunity testsystem
more >>


1-okt-2009
Data I/O
Introduces Flashcore III technology
more >>


30-sept-2009
Accelonix
10th edition Boundary Scan Day
more >>