Teseq

Coupling / Decoupling networks

 

CDN_selection_chart
CDN selection chart
CDN selection chart (2566.67 KB)

 

CDN M Type

Coupling decoupling network CDN M116
CDN_M116
  • Designed for IEC/EN 61000-4-6
  • For PE line application
  • 4 mm banana sockets
   
Coupling decoupling network CDN M016, M210B, M216, M310B, M316, M316B
CDN_M016
  • Designed for IEC/EN 61000-4-6
  • CDN M016 switchable M2 or M3
  • Types with 4 mm banana sockets
  • Performance up to 230 MHz
   
Coupling decoupling network CDN M416, M416-3LN, M516
CDN_M416
  • Designed for IEC/EN 61000-4-6
  • 4 mm banana sockets
  • CDN M516 AE port supplied with CEE socket
   
Coupling decoupling network CDN M325, M425, M425-3LN , M525
CDN_M525
  • Designed for IEC/EN 61000-4-6
  • Mains application up to 25 A
  • 4 mm banana sockets
  • CDN M325 and M525 AE port supplied with CEE sockets
   

Top

 

CDN AF Type

Coupling decoupling network CDN A201, A301, A401
CDN_A401
  • Used for unscreened, unbalanced lines, carrying low current
  • Designed for IEC/EN 61000-4-6
  • 4 mm banana sockets
  • Performance up to 230 MHz
   
Coupling decoupling network CDN A800, A150
CDN_A800
  • Used for unscreened, unbalanced lines, carrying low current
  • Up to 15 lines
  • Designed for IEC/EN 61000-4-6
  • D-Sub sockets
  • Performance up to 230 MHz
   

Top

 

CDN S Type

Coupling decoupling network CDN S150, S200, S250, S400, S900
CDN_S900
  • Used for screened cables
  • Up to 25 lines
  • Designed for IEC/EN 61000-4-6
  • Types with D-Sub sockets
  • Performance up to 230 MHz
   
Coupling decoupling network CDN S501, S751
ISN_S501
  • Used for coaxial cables
  • Designed for IEC/EN 61000-4-6
  • BNC sockets
   
Coupling decoupling network CDN ST08A
ISN_ST08
  • For testing screened, balanced lines for telecommunication ports on ITE equipment.
  • For use with screened RJ45 connections
  • Up to 8 lines/ 4 pairs
  • Designed for IEC/EN 61000-4-6
  • Meets the requirements of CISPR 22, Ed.5.0, Ed.5.2 and Ed.6.0
   

Top

 

CDN USB Type

Coupling decoupling network CDN USB/c, USB/p
CDN_USBc
  • Designed for IEC/EN 61000-4-6
  • USB/c for test central devises
  • USB/p for test periferal devises
   

Top

 

CDN CAN BUS Type

CDNs for CAN BUS application
CDN_CAN
  • Designed for IEC/EN 61000-4-6
  • CAN BUS application
  • Two different types for four or five lines
  • D-Sub-9-sockets
   

Top

 

CDN T Type

CDNs for unscreened balanced pairs, CDN T002 and CDN T004
CDN_T004
  • CDN T002 for one unscreened balanced pair
  • CDN T004 for two unscreened balanced pairs
  • Designed for IEC/EN 61000-4-6
  • 4 mm banana sockets
   
CDNs for unscreened balanced pairs, CDN T210A...T246AS, CDN T411A...T4AS
CDN_T400A
  • CDN T2xxA for one unscreened balanced pair
  • CDN T4xxA for two unscreened balanced pairs
  • Designed for IEC/EN 61000-4-6
  • RJ11 and RJ45 sockets with different
  • pin-arangements as required by the application
   
CDNs for unscreened balanced pairs, CDN T8
CDN_T8
  • For use with one, two, three, or four unscreened balanced pairs
  • Designed for IEC/EN 61000-4-6 and CISPR 35 broadband impulsive noise tests
  • 1000BaseT and PoE application
  • RJ11 and RJ45 sockets
   

Top

 

CDN 10 kHz to 80 MHz

Coupling decoupling network M1 for 10 KHz to 80 MHz
CDN_M116
  • Designed for IEC/EN 61000-4-6 with extended range form 10 kHz to 80 MHz
  • For PE line application
  • 4 mm banana sockets
   
Coupling decoupling network M2 and M3 for 10 kHz to 80 MHz
CDN_M316_10
  • Designed for IEC/EN 61000-4-6 with extended range form 10 kHz to 80 MHz
  • For M2 and M3 application
  • 4 mm banana sockets
   
Coupling decoupling network S9 for 10 kHz to 80 MHz
CDN_S900
  • Used for screened cables
  • Up to 9 lines
  • Designed for IEC/EN 61000-4-6 with extended range form 10 kHz to 80 MHz
  • Type with D-Sub sockets
   
Coupling decoupling network ST08 for 10 kHz to 80 MHz
CDN_ST08_10
  • For testing screened, balanced lines for telecommunication ports on ITE
  • equipment.
  • For use with screened RJ45 connections
  • Up to 8 lines/ 4 pairs
  • Designed for IEC/EN 61000-4-6 with extended range form 10 kHz to 80 MHz
   

Top

 

CDN CISPR 15

Coupling decoupling network for CISPR 15 measurements
CDN_M016
  • Designed for IEC/EN 61000-4-6 and CISPR 15/ EN 55015
  • Types with 4 mm banana sockets or sub-D connectors
  • Performance up to 300 MHz
   

Top

 

CDN/ISN CISPR 22

Impedance stabilization network ISN T2A
ISN_T2A
  • For use with one unshielded balanced pair
  • CISPR 22, Ed.5.2, 2006 and EN 55022 Sept. 2006 (IEC/CISPR 22: 2005 modified) for Cat.3 and Cat.5
  • Changeable pin-arrangements with RJ11 and RJ45
  • Can be used as CDN for IEC 61000-4-6 immunity tests
   
Impedance stabilization network ISN T4A
ISN_T4A
  • For use with one or two unshielded balanced pairs
  • CISPR 22, Ed.5.2, 2006 and EN 55022 Sept. 2006 (IEC/CISPR 22: 2005 modified) for Cat.3 and Cat.5
  • Changeable pin-arrangements with RJ11 and RJ45
  • Can be used as CDN for IEC 61000-4-6 immunity tests
   
Impedance stabilization network ISN T8
ISN_T8
  • For use with one, two, three, or four unscreened balanced pairs
  • CISPR 22, Ed.5.2, 2006 and EN 55022 Sept. 2006 (IEC/CISPR 22: 2005 modified) for Cat.3 and Cat.5
  • 1000 BaseT and PoE application
  • Changeable pin-arrangements with RJ11 and RJ45
   
Impedance stabilization network ISN T8-Cat6
ISN_T8_Cat6
  • ISN T8 for cable category 6 (LCL 75/60 dB) and RJ45 connection
  • For use with one, two, three, or four unscreened balanced pairs CISPR 22, Ed.5.2, 2006 and EN 55022 Sept. 2006 (IEC/CISPR 22: 2005 modified) for Cat.6
  • 1000BaseT and PoE application
  • Transmission bandwidth 250 MHz
  • Can be used as CDN for IEC 61000-4-6 immunity tests
   
Impedance stabilization network ISN ST08
ISN_ST08
  • For use with screened RJ45 connections
  • Up to 8 lines/ 4 pairs
  • Meets the requirements of CISPR 22, Ed.5.2
  • Design given in figure D.11 of CISPR 22, Ed.5.2
  • Can be used as CDN for IEC 61000-4-6 immunity tests
   
Impedance stabilization network ISN S501
  • For use with coaxial lines
  • BNC connectors
  • Meets the requirements of CISPR 22, Ed.5.2
  • Design given in figure D.9 of CISPR 22, Ed.5.2
  • Can be used as CDN for IEC 61000-4-6 immunity tests
   
CAS ISN, calibration kit for ISN T
CAS_ISN
  • Meets CISPR 22 ed. 5.2 and CISPR 16-1-2
  • Optional extensible for measurements on ISN T2 and ISN T8-Cat6
  • Measurements for common mode impedance, phase angle, voltage division factor, decoupling attenuation (isolation) and longitudinal conversion loss (LCL)
   
Magnetic fixture for ISN T2A, ISN T4A, ISN T8, ISN T8-Cat6 or CDN T8
FIX_ISN_with_ISN
  • Improvement of the ISN earth connection to steel surfaces
  • Allows vertical positioning of the ISN (chamber wall)
  • Easy positioning of the ISN in the setup
  • Ruggedly designed
   

Top

 

CDN CISPR 35

CDNs for unscreened balanced pairs, CDN T8
CDN_T8
  • For use with one, two, three, or four unscreened balanced pairs
  • Designed for IEC/EN 61000-4-6 and CISPR 35 broadband impulsive noise tests
  • 1000BaseT and PoE application
  • RJ11 and RJ45 sockets
   

Top

 

Coupling Networks per IEC/EN 61000-4-19

CDN per IEC/EN 61000-4-19
CDND M316-02
    IEC/EN 61000-4-19 specifies the differential voltage test in the frequency range 2 kHz to 150 kHz. Teseq offers with CDND M316-2 a coupling/decoupling network for single phase mains application. It can be used for both application with and without protective earth connection. The CDND is fully complaint with the requirements of the standard and provides a simple and reliable method of injecting RF energy into the equipment under test (EUT).
   
Current Transformer per IEC/EN 61000-4-19
CT 419 5
    IEC/EN 61000-4-19 specifies the differential current test in the frequency range 2 kHz to 150 kHz. Teseq offers with CT 419-5 a 1:1 transformer for testing EUTs like electricity meters. The CT 419-5 is fully compliant with the requirements of the standard and provides a simple and reliable method of injecting differential mode current into the equipment under test (EUT).
   

Top

 

Coupling Networks per IEC/EN 61000-4-16

CD per IEC/EN 61000-4-16
CN M332-AC
    IEC/EN 61000-4-16 specifies the design and performance of a range of coupling networks. Each coupling network is related to the type of cable and connector. An specific 60 dB decoupling network is required in addition to
   

Top

Request information

 

Latest News

twitteryoutube

jun-2017
EM Test New ESD Simulator

NX 30 - New 30kV ESD Simulator with Bleed-off function.
more...


EM Test Surge Generator for Solar Panel testing
New vSurge NX 20
more...


3-phase Power Sources from EM Test
Netwave Series
more...


MPE - World First Gb Ethernet Filter
Low-Pass EMI Filter
more...


Rental solutions for EMC instrumentation
Accelonix Rental Service
more...


05-may-2017
Accelonix at E&A 2017
Accelonix exhibiting at Electronics & Applications 2017.
May 30 May to June 1th, Jaarbeurs Utrecht.


22-feb-2017
TestWay Seminar

DFx Software Tools to Optimize PCBA Manufacturing & Test Strategy.
April 4, Eindhoven


08-feb-2017
Yxlon FeinFocus

Non-Destructive X-ray Inspection Technology for Electronics.
more...


01-feb-2017
Aster twSystem

New system level PCB viewer.
more...


26-jan-2017
Hesse New BJ 955/959

New Bonder platform for Manual and Automated Heavy Wire Bonding.
more...


18-jan-2017
Akrometrix

Thermal Warpage & Strain Metrology Measurement Systems.
more...


27-nov-2016
CyberTECHNOLOGIES
Non-Contact 3D Surface Metrology Measurement Systems.
more...


15-nov-2016
TPT Wire Bonding Workshop
Learn about Wire Bonding and discover the TPT Solutions during this Free Workshop!

 


sep-2016
XRH Count
Revolution in automatic, contactless SMT component counting!
more...


june-2016
FEE EMC Seminar
Thank you for visiting us in St-Katelijne-Waver


may-2016
Teseq ITS 6006B
Radiated immunity test system up to 6GHz, Second Generation released
more...



Teseq NSG 4070B
RF immunity test system up to 1GHz. Now also supports draft version (2015) of ISO 7637-4
more...



Teseq NSG 4060
Meets new immunity testing requirements range 15kHz-150kHz
more...



MPE Plug-in Tempest Filters
Protect your IT systems with this range of convenient, plug-in TEMPEST filters
more...


mar-2016
Accelonix BV has moved!
Accelonix has moved to a new office space since March 12th 2016
more...


jan-2016
Data I/O LumenX
Data I/O Ultra-Fast eMMC Programming!
more...


Accelonix News Archive