Teseq
Coupling / Decoupling networks
|
CDN selection chart
|
 |
|
|
Coupling decoupling network CDN M116
|
 |
- Designed for IEC/EN 61000-4-6
- For PE line application
- 4 mm banana sockets
|
|
Coupling decoupling network CDN M016, M210B, M216, M310B, M316, M316B
|
 |
- Designed for IEC/EN 61000-4-6
- CDN M016 switchable M2 or M3
- Types with 4 mm banana sockets
- Performance up to 230 MHz
|
|
Coupling decoupling network CDN M416, M416-3LN, M516
|
 |
- Designed for IEC/EN 61000-4-6
- 4 mm banana sockets
- CDN M516 AE port supplied with CEE socket
|
|
Coupling decoupling network CDN M325, M425, M425-3LN , M525
|
 |
- Designed for IEC/EN 61000-4-6
- Mains application up to 25 A
- 4 mm banana sockets
- CDN M325 and M525 AE port supplied with CEE sockets
|
|
Coupling decoupling network CDN A201, A301, A401
|
 |
- Used for unscreened, unbalanced lines, carrying low current
- Designed for IEC/EN 61000-4-6
- 4 mm banana sockets
- Performance up to 230 MHz
|
|
Coupling decoupling network CDN A800, A150
|
 |
- Used for unscreened, unbalanced lines, carrying low current
- Up to 15 lines
- Designed for IEC/EN 61000-4-6
- D-Sub sockets
- Performance up to 230 MHz
|
|
Coupling decoupling network CDN S150, S200, S250, S400, S900
|
 |
- Used for screened cables
- Up to 25 lines
- Designed for IEC/EN 61000-4-6
- Types with D-Sub sockets
- Performance up to 230 MHz
|
|
Coupling decoupling network CDN S501, S751
|
 |
- Used for coaxial cables
- Designed for IEC/EN 61000-4-6
- BNC sockets
|
|
Coupling decoupling network CDN ST08A
|
 |
- For testing screened, balanced lines for telecommunication ports on ITE equipment.
- For use with screened RJ45 connections
- Up to 8 lines/ 4 pairs
- Designed for IEC/EN 61000-4-6
- Meets the requirements of CISPR 22, Ed.5.0, Ed.5.2 and Ed.6.0
|
|
Coupling decoupling network CDN USB/c, USB/p
|
 |
- Designed for IEC/EN 61000-4-6
- USB/c for test central devises
- USB/p for test periferal devises
|
|
CDNs for CAN BUS application
|
 |
- Designed for IEC/EN 61000-4-6
- CAN BUS application
- Two different types for four or five lines
- D-Sub-9-sockets
|
|
CDNs for unscreened balanced pairs, CDN T002 and CDN T004
|
 |
- CDN T002 for one unscreened balanced pair
- CDN T004 for two unscreened balanced pairs
- Designed for IEC/EN 61000-4-6
- 4 mm banana sockets
|
|
CDNs for unscreened balanced pairs, CDN T210A...T246AS, CDN T411A...T4AS
|
 |
- CDN T2xxA for one unscreened balanced pair
- CDN T4xxA for two unscreened balanced pairs
- Designed for IEC/EN 61000-4-6
- RJ11 and RJ45 sockets with different
- pin-arangements as required by the application
|
|
CDNs for unscreened balanced pairs, CDN T8
|
 |
- For use with one, two, three, or four unscreened balanced pairs
- Designed for IEC/EN 61000-4-6 and CISPR 35 broadband impulsive noise tests
- 1000BaseT and PoE application
- RJ11 and RJ45 sockets
|
|
Coupling decoupling network M1 for 10 KHz to 80 MHz
|
 |
- Designed for IEC/EN 61000-4-6 with extended range form 10 kHz to 80 MHz
- For PE line application
- 4 mm banana sockets
|
|
Coupling decoupling network M2 and M3 for 10 kHz to 80 MHz
|
 |
- Designed for IEC/EN 61000-4-6 with extended range form 10 kHz to 80 MHz
- For M2 and M3 application
- 4 mm banana sockets
|
|
Coupling decoupling network S9 for 10 kHz to 80 MHz
|
 |
- Used for screened cables
- Up to 9 lines
- Designed for IEC/EN 61000-4-6 with extended range form 10 kHz to 80 MHz
- Type with D-Sub sockets
|
|
Coupling decoupling network ST08 for 10 kHz to 80 MHz
|
 |
- For testing screened, balanced lines for telecommunication ports on ITE
- equipment.
- For use with screened RJ45 connections
- Up to 8 lines/ 4 pairs
- Designed for IEC/EN 61000-4-6 with extended range form 10 kHz to 80 MHz
|
|
Coupling decoupling network for CISPR 15 measurements
|
 |
- Designed for IEC/EN 61000-4-6 and CISPR 15/ EN 55015
- Types with 4 mm banana sockets or sub-D connectors
- Performance up to 300 MHz
|
|
Impedance stabilization network ISN T2A
|
 |
- For use with one unshielded balanced pair
- CISPR 22, Ed.5.2, 2006 and EN 55022 Sept. 2006 (IEC/CISPR 22: 2005 modified) for Cat.3 and Cat.5
- Changeable pin-arrangements with RJ11 and RJ45
- Can be used as CDN for IEC 61000-4-6 immunity tests
|
|
Impedance stabilization network ISN T4A
|
 |
- For use with one or two unshielded balanced pairs
- CISPR 22, Ed.5.2, 2006 and EN 55022 Sept. 2006 (IEC/CISPR 22: 2005 modified) for Cat.3 and Cat.5
- Changeable pin-arrangements with RJ11 and RJ45
- Can be used as CDN for IEC 61000-4-6 immunity tests
|
|
Impedance stabilization network ISN T8
|
 |
- For use with one, two, three, or four unscreened balanced pairs
- CISPR 22, Ed.5.2, 2006 and EN 55022 Sept. 2006 (IEC/CISPR 22: 2005 modified) for Cat.3 and Cat.5
- 1000 BaseT and PoE application
- Changeable pin-arrangements with RJ11 and RJ45
|
|
Impedance stabilization network ISN T8-Cat6
|
 |
- ISN T8 for cable category 6 (LCL 75/60 dB) and RJ45 connection
- For use with one, two, three, or four unscreened balanced pairs CISPR 22, Ed.5.2, 2006 and EN 55022 Sept. 2006 (IEC/CISPR 22: 2005 modified) for Cat.6
- 1000BaseT and PoE application
- Transmission bandwidth 250 MHz
- Can be used as CDN for IEC 61000-4-6 immunity tests
|
|
Impedance stabilization network ISN ST08
|
 |
- For use with screened RJ45 connections
- Up to 8 lines/ 4 pairs
- Meets the requirements of CISPR 22, Ed.5.2
- Design given in figure D.11 of CISPR 22, Ed.5.2
- Can be used as CDN for IEC 61000-4-6 immunity tests
|
|
Impedance stabilization network ISN S501
|
 |
- For use with coaxial lines
- BNC connectors
- Meets the requirements of CISPR 22, Ed.5.2
- Design given in figure D.9 of CISPR 22, Ed.5.2
- Can be used as CDN for IEC 61000-4-6 immunity tests
|
|
CAS ISN, calibration kit for ISN T
|
 |
- Meets CISPR 22 ed. 5.2 and CISPR 16-1-2
- Optional extensible for measurements on ISN T2 and ISN T8-Cat6
- Measurements for common mode impedance, phase angle, voltage division factor, decoupling attenuation (isolation) and longitudinal conversion loss (LCL)
|
|
Magnetic fixture for ISN T2A, ISN T4A, ISN T8, ISN T8-Cat6 or CDN T8
|
 |
- Improvement of the ISN earth connection to steel surfaces
- Allows vertical positioning of the ISN (chamber wall)
- Easy positioning of the ISN in the setup
- Ruggedly designed
|
|
CDNs for unscreened balanced pairs, CDN T8
|
 |
- For use with one, two, three, or four unscreened balanced pairs
- Designed for IEC/EN 61000-4-6 and CISPR 35 broadband impulsive noise tests
- 1000BaseT and PoE application
- RJ11 and RJ45 sockets
|
Top
Request information
|